Frank: Does anybody have the programming information, hookup andor manuals for the smart II series of Staefa controls?
Reply
moiscell robinson: I need confimation that you can repair the following staefa cards---Staefa Net Controller X091-72000---SM2-DDC 091-60210-81 Phase Cut 0-20vdc---SM2- 091-60230-81 0-10VDC ---SMIITOOL A- SMART TOOL SERVICE TOOL---NCRS 091-MS-180-01---NCREA ---SM2-FNC 091-60210---SM2-VAV---SMVU-VPLEAES CONTACT ME OR SEND EMAIL TO CONFIRM I WOULD APPRECIATE SOME REFERENCES AND NUMBERS TO CONFIRM BUSINESSPHONE 302-831-8576THANK-YOU Moiscell Robinson
Reply
Charles Wilson: You may have found a solution to the Staefa Smart card repair problem, but we do repairs.Please contact. Thanks
Reply
Greg Goffaux: Where can I get copies of Staefa Smart Tool I and II Manuals?
Reply
Bruce Locke: We have an SMii Tool that is not functioning.Can we ship it to you for repair?
Reply
Larry Vasquez: Need manual for an Staefa Controls program. Only info we have is Staefa Controls c. 1991. Elsewhere we see THR 200 OSA.Please help! If more info is needed please advise as where to find it.We will be upgrading soon, but in the meantime we need this manual.
Reply
Bijukumar: Dear sir,Can I please get the service manual and catalouges of RDK 999
Reply
Chris Kartson: I need wiring digrams and smart II DDC programing info. I have the Smart tool but no info on the ddc card. Thank you
Reply
John Beerman: You repair Smart II Service Tool.
Reply
dave harper: I am looking for electrical schematics, drawings, or anything I can use to troubleshoot this kind of control system. All previous information has been lost or discarded. I am a HVAC Tech for the USPS and can not find any information on this type of control system. All I have is a small booklet Staefa Integral Smart IITool, Version 2.0, Users Guide that I found inside the control panel.
Reply
ZAFAR IQBAL,SYED: PLEASE QUOTE .WE ARE LOOKING FOR A NEW PART(RDK-22).IF YOU CAN NOT QUOTE THAN PLEASE LET US KNOW SOME ONE WHO HAS IT.THANKSENQ NO.SMT- SMT-Q448 BID DUE DATE: APR, 2009===========================qty;1CONTROLLER , --: TYPE: TEMPERATURE; RANGE: 0 TO 50 DEG C; RATING: 24 VAC, 5060 HZ; CONNECTION: PLUG IN; ADDITIONAL DATA: OUTPUT RATING: Y1: 5(2) A 220 VAC, Y2: AC; 5(2) A 220 VAC;WITH 25 PINS, FOR SCS-KLIMO CONTROL 24 V SCS-KLIMO RDK-922 CARRIER CORPUNITEDTECHNOLOGIES PN# RDK-22 APPLICATION: FOR HVAC UNIT IN EAST DAMMAM, EAST AL-KHOBAR (CARRIER AHU MODEL 39E D17 AND ACCU MODEL 38AE-044). MFR NAME:CARRIER CORPORATION MFR PN :RDK-22
Reply
Dave Smith: We are trying to replace discharge air sensors on several Staefa Smart II Fan controllers and we cannot get the same sensors as currently installed. We need to figure out how to calibrate the controllers to the new sensors, but while we have information on the system, it refers us to this manual (362-55401) for more information. I need to know if there is somewhere we can obtain this manual or the appropriate information for programming the smart II controllers. We have both the PCTools and the Handheld tool.Thanks for your help.
Reply
Chris: Whats involved with replacing a smart1 card with a smart2 ?
Reply
Jay: I replaced the old red T30 sensors with the new 2x4 handy box looking T30 and used an 09 range module.
Reply
Thomas Shanahan : How do you disable the offset for temp in the programing of the Smart 2 card?
Reply
Anthony Barcelo: I am looking for a Smart II tool for service and calibration of our Tstats and VAV boxes. Also the service manual with the toolI need prices and avaliavility.Thank you very much and have a great day
Reply
Robert Clemons: We have a MS 1800 controller that stopped talking to the computer and we are looking for some one to repair it or replace it with a recondition one. thanks for any help you can give us.
Reply
Craig Pickenpaugh: We are replacing a SM2VAV-8633 with our controller. The existing system is showing a fiber optic cable connecting this board with a speed control board SM2-FSP2775. I was wondering if the SM2-FSP2775 has a option other than fiber optic for fan control. Can it take a 010 volt signal. I thought I seen a manual on this but I cant find it now. It looked like a 010 signal was going to terminals 2 and 5 on the speed control board. Can I wire my 010 Volt signal to these terminals for fan control?
Reply
Jason Whatley: I would like for you to provide us with some prices for the following equipmentservices - FC Card - 0-10v dcDDC Card - 0-10v dcms1800 front end board 09, 04, 02 and 01 range modulesService ToolPrice to repairrefurbish FC cards and DDC cards.Also, I would like to know turn around time on repairs. Thank you.
Reply
Keith Palmer: The issue with your Staefa Control System SMIITOOLA controller is that it is no longer responding to input commands or displaying any readings on the screen. This unresponsiveness is causing disruptions in your HVAC systems operations, leading to inefficient temperature control and potentially affecting the comfort of your workspace. Based on the symptoms described, it is likely that there is a malfunction within the internal components of the controller, necessitating a repair or replacement to restore proper functionality. The estimated cost for a replacement Staefa Control System SMIITOOLA controller ranges from $300 to $500, depending on the seller and availability of the unit. To ensure seamless operation of your HVAC system, it is advisable to seek professional repair services or purchase a new controller
Reply