Welcome to Melco

unofficial service & repair forum

We repair a wide range of Melco Equipment.

Ask questions, or call 1-336-969-0110 for faster service.

Use the search bar above to find specific manufacturers.


Why to send us your work?

To receive more information about your unit then fill out the email form below
and we will be in contact with you within 24 hours.

Comments for Melco

2 comments found.
Mark Howell: I have a Melco Emt 10-4T and apparently had a power surge. It seems to have burned up some boards, at least some components. I replaced the power supply because I could see one component fried. Still cant get the machine to work. It will display e-stop engaged. I have disconnected the emergency stop buttons but it still doesnt work.
Reply
  
vicki palonen: i have a emt 10t phase 2 it just died i feel it must be the power supply no lights nothing do u repair power supplys i checked with melco and they will replace it new for 1200 or rebuilt for a 1000 i would love to have other options its a great machine i bought it new in 98 i really need to get it working again this is my lively hood thanks vicki
Reply
  
roger koren: the screen shows nothing when i start up the machine. it is blank.
Reply
  
roger koren: the screen shows nothing when i start up the machine. it is blank. it is not a monitor. it the screen where you insert the 3 1/2 floppys.
Reply
JACK CROWLEY: CAN THEY BE REPAIRED OR ANY AVIALABLE. THANKS
Reply
JACK L FEAK: We have a Melco EMT 10/4T machine with a start-up boot problem. I believe there may be a electronics hardware problem (memory error?). Error is BOOT DISK ERROR_. After replacing the floppy disk drive and new boot floppy disk a closer examination indicates a problem in the self test routine (I think). The system used to go through the self tests and then looks for the floppy but now stops after the RSA Memory Test PASSED, and immediately displays B4 and stays there until enter is pushed again.Do you have any idea where to start troubleshooting? I have an electronics degree so you can talk as technical as you wish. We were hoping to diagnose the problem and send you only the defective part for repair. (my guess is dynamic ram error bank 4 on CPU board but just a guess). See the following boot display sequences. Any Help would be greatly appreciated!System stack PASSEDRSA Memory PASSED (then jumps immediately to B4 and stays until Enter is pushed)Bunch of corrupt characters now displayed (stays on that screen until Enter is pushed)Lan Card Locate PASSEDLAN EEPROM LOAD PASSEDSelf-test PASSEDEBIOS V1.04 928KINSERT BOOT DISK_BOOT DISK ERRORmachine infoMelco EMT 10/4T Model 01050002Serial # 790799Mfg date 01/2000
Reply
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z