Comments for Rustronic

5 comments found.
Godfrey Saldanha: The MMI for our Ruston Gas turbine control system has failed. We are unable to obtain a new MMI from the manufacturer (NEC NL10276AC24-01). We wish to enquire if you can repair this MMI and load the software. We have the neccessary software. including the intelligent display software Rustronic MKII software and Rustronic utilities software.Is there a procedure to load the software?
Reply
  
frank krämer: Dear Sirswe are looking for a company which able to change the Rustronic PLC parameters, can you offer us your expert to come to Germany.Best regardsTUBAFrank Krämer
Reply
  
Do Trong Nghia: We are using turbine TB-5000. Now speed is panel control. I wish control speed by analog input. May I have the program of this method?
Reply
  
souane lak: I did a loading to PPM1 slot0 and PPM1 in slot1 but the LEDs on PPM1 slot1 are still on.What 's the problem?I did loading using VT100 terminal.
Reply
  
Haresh PChavda: Dear sir with referencve to our organization we have installed Rustronic MKII software RP2 for EGT turbine (European Gas Turbine ) this system generate a message around 4000 for troubleshotting so if i want to know all the message how its create through varuious types of input output comming from field device from the software ..can u send the document if i give the all details or can u send one person for servicing or checking of all interlock and all those thing so kindly revert back to me on same mailalso send u required all details from our organization mine:- contact details :- hpchavda@rediffmail.com,hpchavda2003@yahoo.comreagrds thanks Hraesh P Chavda Alembic Limited Baroda Gujarat India
Reply
  
Muhammad: Need Control Logic (Digital and Analog) of Rustronic MKII
Reply
  
reza ramezani: Dear Sirwe need a copy of PLC and monitoring program for SGT-100-2s (Typhoon) MK II ; star fuel valve. we will be highly appriciate if you quote us the above software.best regards
Reply
Do Trong Nghia: Dear Sir,We are using turbine TB5000 to drive water pump.I want to force the supply valve (SOL-11)and vent valve( SOL-12). But I can not force them by command CHG SOL11,1. When I type this command, the LED on card is on in short time. There is no signal at terminal. What Module must I choose? Why not I_O Module?I also want to control speed by analog input, may I use the PID control?I hope receive your reply soon. Thank you!Best Regards.Do Trong Nghia
Reply
  
Dilip Hutheram: Please find below the complete part numbers for the Rustronic vibration modules I required for the Gas Turbine. Module 4509 Part no. : 4509 20 64 07004230 20 950279 1 2 (SR6113 06) (SR6129 06) Module 4502 Part no. : 4502 30 64 07004230 30 950279 1 5 (SR6127 03) (SR6113 23) Module 4504 Part no. : 4504 42 64 07004230 42 950279 1 6 (SR6123 03) Module 4510 Part NO.: 4510 27 64 07004230 27 50279 2 7 (SR6131 02) (SR5946 05) I hope this helps. Please forward me an official quote.Please forward me your e-mail, so I can send you photos of these cards. Kind regards Dilip HutheramE&I Superintendent Newcastle Co-GenerationCell: 083 631 9693Tel: 034 3284488Fax: 034 3284489Email: dilip.hutheram@newcogen.co.za
Reply
    
simon Jackson: Hi Please could you quote me price and delivery on a Rustronic 4509 vibration card.Kind rgeardsSimon Jackson
Reply
  
Torben Espoe: I have tried to program this pcb for my washing machine, but it keeps coming up with E90 when I turn the machine on, as if it isn 't programmed. But when I check the program adresses, the data is correct. I have noticed that the software ver. is W2C01551, is there perhaps an other thing that I need to do? other than pressing the two top buttons for saving the data?Best regardsTorben
Reply
    
Magnus: Hello! I 've got problem with my washing mashine. That 's alert E90 about 15 seconds after I pushed the start button och nothing else is happend. DATA:Precond elettronica type 451516811Type E.Z Assembly: 132191552Type E.Z Board:124307062SW Ver.:UDA30202T70 WK:52 05 Op:4410
Reply
  
Mellah: Bonjour, Monsieur;Afin de me permettre de lire les modules du software, et de bien comprendre le fonctionnement des turbines installées à notre site Sonatrach, j 'ai besoin de m 'envoyer un document qui explique les instructions utilisées dans des modules par exemple ( DEF: MODULE:TURBINE_GAS_FUEL; PROT:2; GLOBAL:DISTAG; GLOBAL:DISSTRING; GLOBAL: LOAD_STRINGS; GLOBAL: STRINGS_LOADED; DEF: TASK:INI(3); ID:DEFAULT_TSK_ID; PER:1; ACT:MESSLOAD; REQ: SYMINIT; LET: NOTANN=1; GOSUB:TSK_STOP; DEACT:MONITOR; et merci monsieur;
Reply
  
wahalim: We have few unit cards CT91002 2 need to repair.Pls estimed cost repair and delivery.Few CT91002 components burnt
Reply
Ignacio Pinedo: I have an SCM card PN CT92475A 03 on a rustronic control system that is causing me trouble. The customer has a replacement card with P N CT92475A 01 and I do not know what the differences are. Can you support?Customer is due to replace this sytem for a woodward micronet in the next four months.Regards.
Reply