Have an Eu alarm on a brand new Kouwa chiller unit on a Mazak ST550. can not clear. Any suggestions?
The condenser coil on my kmv-150-m34 unit is leaking , which is causing a chiller malfunction alarm. Does anyone know who to contact for a replacement condenser coil ????????
spare parts price and delivery time for a compressor for KMV 110 M21-A
I have a Kouwa chiller Model KMV-150-M15-B I keep getting a EJ alarm which is not in my manual. Any ideas???
I have a customer that is using a kouwa KMV-110-M10-A oil cooler can you sendt my a parts list.KMV-110P-M10-C01
I Have Model # KMV-75-M02-A W/ No Manual Alarm E1 on Unit.
bonjour je recherche un compresseur R407C KOUWA LIQUD TUNER KMV-150-M14TARIF + FRAIS DE PORT ET DELAISSALUTAITONS
Mazak 6800 HMC uses Model KMV-150-M14-C. Had a 30 amp trip shut down machine. Traced to low oil in the in the Hysol (Left side oil fill port). Still tripped. The CM motor starter 4th from left was dirty with carbon. We changed it out. Still trips. We ohm'ed out the motor. Seemed good. Thinking what the motor is spinning had frozen up but the e stop won't go away and the chiller never starts. I get the 4 dashes at boot up and I can push the parameter button to see A200. Nothing else shows on the display, no alarms.
I am looking for a flow switch. for model #KOEJ112BOV Serial # 1510-R0490-N81. Hope you can help
Dear all :We are looking control Board, P/N : NAYUTA NB-584 01855B = 1 unit. Pls advice your price + freight cost + lead time to us.Best regards,Ms. Ying
hello i have a kouwa chiller on my mazak its flashing EJ on unit wanted to see what this meant thanks
Looking for pricing for a compressor # C-2NR153H3a (808-051-83) and a fan motor # VAS405BS-42. Both from a Kouwa chiller unit # KMV-150-M14-A
I need a compressor for a kouwa kmv-150-m15-b but the BTU of the unit is not listed in the maunual. It's a 220v 3ph system.Do you sell the compressors? If so how much are they and what is the BTU rating?Thanks!!
Getting an E7 alarm on the unit. What is the normal cause of this?
Kouwa Liquid tuner Fan motor D-PT-Z 222-S required & send details in India sale& service contact no , Email address, This liquid tuner using for Mazak m/c ,
Good morning our unit a KMV-150-M16-C. tHREW AN E8 fault. Per Mazak tech he said it was a bad compressor. We are trying to locate a compressor for this unit. We have a very hot job to run on this machine and need it repaired asap. Any help would be greatly appreciated. If you need additional info call Alan E. Trimue at 989-274-5675. Thank you.
I need a troubleshooting manual for KOUWA LIQUID TUNER model :GK-150T-FZC-BE (english langauge).Now machine alarm code show E6 .Thank you
Our tuner got a E9 error and then the controller went out. Pulled the controller cover and found NB0793 is smoked. We are trying to locate another circuit board to replace it with or maybe even have this one repaired; whatever is the quickest. Thanks, Chris Haigler
WORKING ON CHILLER UNIT ON A MAZAK AND IT KEEPS SHUTING DOWN WITH AN E6 ERROR CODE . I'VE CLEANED THE COIL AIR FILTERS ALL THE Y SUCTION STRAINERS . BUT WHEN I POWER UP MACHINE FAN COMES FOR TWO SECONDS AND QUITS. NEED SOME HELP PLEASE
Hello there,We have Mazak 410 VMC with Serial no. 175268. There is Kouwa Liquid Tuner installed in it for spindle lubrication with Model no. KMV-75-M02-B with Mfg. No. 0607-M9038. It shows EE alarm on display and we are not capable to remove it. Kindly provide a suitable person or mail-id or if you can provide support through mail-id. Our machine is idle from last 20 days. Thanks & RegardsRashpal SinghIn-charge CNC SectionFor Ambika Overseas,Model House Road, Basti Shiekh,Jalandhar - Punjab (INDIA)
we have a Mazak VCN 510 C serial 162546 march 2003 with a schiller KMV-75-M02 the board NAYUTA NB-584 is out of orderWe do not know if the display is ok or notpls your comments asap we are in a hurry with that machine cordially
I am getting an EA fault code on tuner display as soon as the unit is powered up. The EDM that it is attached to comes up with a false U794 high fluid temp alarm. I have checked all the wiring and fuses as well as the phasing of the motors.
Hi , would you mind to give me a quotation for the chiller unit Model Kouwa Model KMV-150-M15.Thank you in advance.
HiI need a compressor motor for a KMV-150-M14-C, we require this part urgently so details of agents in the UK or Europe would be helpful.is there a specification available for this compressor so we can source our own unit?
HiI need a replacement compressor motor for the above unit.Can they be sourced in Europe or do I need to import? either way I need cost and delivery time urgently.Steve
Pls technical support
I need a troubleshooting manual for KOUWA LIQUID TUNER model: KCT7-A52N (english langauge). Now machine alarm code show E2. Thank you Peerasij
We have a new chiller that is missing a ribbon cable connecter.Is this something you could supply for us. Or would you know what we need order.Thanks John Swank (773)501-7281
Hello, We have a bad compressor SANYO part: C-2RN153H3A code: 80805183 This it installed on KOUWA LIQUID TUNER model: KMV-150-M16-B Mfg. No. 0601-M7189 Could you send us please price and delivery time. We are in Nuevo León, México. Please, send the answer as soon as posibble. Thanks.
I have a Showa temperature controller Model#sho-650-104-lfvc-dc in the instruction manual it says to contact you for service.Is ths correct? and if it is do you have parts and tech support. our unit is running but we are going to need filters ect. down the road.thank you for your time,Joe colombo
Kouwa KMV-150-M16-A throws an E8 code. Ambient pressure is around 140psi at 75 degrees. Unit will run for about 3 -5 minutes and throw the code. Current to the compressor is about 3.6 amps. Is this a good value? On page 8 of the check out procedure the term \"thermal setting value\" for current is listed in the E8 alarm procedure. What is the normal thermal setting value for current draw?
What are the normal operating pressures and current load for this unit when running properly? Any ideas on what needs to be replaced?
Hello,i would like to have price and deliveryconditions for a compressor KOUWA type KMV-150-M14-C-002 on R407 C gas and 3 x 200 V 50/60Hz.Can you inform me as soon as possible please ?I am a refrigeration company in Belgium (www.golling.be)Best Regards,Alain GOLLING
Hello,i would like to have price and deliveryconditions for a compressor KOUWA type KMV-150-M14-C-002 on R407 C gas and 3 x 200 V 50/60Hz.Can you inform me as soon as possible please ?I am a refrigeration company in Belgium (www.golling.be)Best Regards,Alain GOLLING
The above Model is on a Machine where I continually get an \"E8\" Error for Thermal Relay Overload. The Compressor will run for no more than 1 minute. Amps or Watts run high. Seems like an internal failure on Compressor. Any other thoughts before I replace Compressor? Condenser Coil is clean, great airflow. Nothing noticeable at Liquid Filter screen before Cap Tube.Also on this Unit it says Refrigerant is R407C. Any ideas on how much Refrigerant is in System in pounds?Any Tech info on this unit in regards to the Refrigeration cycle would be great.Thank you,Andrew Maass
Type : KCT 7 -A52n-ASerial : 0807-H0256
I have a customer that is using a kouwa KMV-110-M10-A oil cooler can you sendt my a parts list.Mandervelt J.M.Gemacool Genk,Belgie
Looking for a facility to repair our Kouwa hydraulic chillers ( model KMV-150-M16-B ). Are you interested?
I have a manuel for the Kouwa model: KMV-150-M16-B-002 but not a parts list so I can order a cover for the wires above the condenser and a cover for the reset switch. That\'s just a start, having the parts list would be very helpful.
Can the temp diff. be set any greater on a KMU-150-M16-B liquid tuner? the system currently has about 1 deg C between on/off cycle. Orignial compressor locked up. Charge was correct. We believe the excessive start/stop of the unit caused lock-up
Hi Mr/Mrs,Please advise your availability and price of compressor and main board for below machine type:KOUWA liquid tuner model KCT7-A52NThose parts to be delivered to Jakarta Indonesia.Best Regards,Heru
Kindly let us know whether there is any Kouwa chiller service facility in India.
Do you sell compressor pumps for a KMV-150-M14? If not can you tell me where I can locate one. Thank you, Gary
Need to know were we can get a compressor for a model KMV-150-M15-A please respond soone, Thanks
Please let me know where i can get New or Rebuilt Liquid Tuner # GKN-75-HFVC
Hello,Does anyone have a list of fault codes? Or the \"Troubleshooting Guide?\"Thank you.
I have a customer that is using a Kouwa Mod# KMU-150-M-16-B S/N 181776 oil cooler. Can you tell me what pressures to expect and how much 407C is supposed to be in the unit? We just replaced a stuck compressor and my suction pressure is at 0Psi. Performed system flush, installed new strainer and cap tube. Mazak hasn\'t a clue.ThanksJohn ArrinigtonHolohan Inc.Kankakee,Illinois
I have a KOUWA liquid tuner MODEL KMV-150-M14 using R407C refrig. I have installed a new compressor in this unit and need to know the amount of refrigerant to install in the unit. Iwould also like the running pressures thank you
I have a model kmv-110-m10-a, and it is used as a spindle coolant chiller and pump for a Masak 510 mill. The problem is that I am getting three alarms. The chiller unit in giving an E-9 alarm ( Oil pressure (flow) is lowered.) Consequently, that is generating two alarms on the masak machine side. 206 Spindle Lube chiller malfunction. And also, 392 Thermal Displacement offset Error. I\'m sure both of the masak alarms are related to the chiller alarm. My Question is, what would cause the chiller unit to generate the E9 alarm? Plugged suction strainer? Pump going bad? Motor? The unit is only about three years old. Any advise would be greatly appreciated. P.S. The problem is intermitant. And can usually be cleared by powering off unit and machine, and powering back on. Thank you, Nathan Olson Northland Machine Inc.Grand Rapids MN218-328-6479
Check to see if you have a Sanyo, model number C-2RN153H3A-tse or possibly a Toshiba TH207JA / TG240X2-FLwww.smallchiller.com
#Kouwa by Joel ARCHULETA on 2024-10-31 16:22