Socapel Service & Repair Forum

Dear Concern, Please see under below detail then quote rate and also share performa invoice now on first priority.1)SAM-DA-400/480-07N-P4N-E 06 PcsI’m waiting your Quick and positive reply

— Posted by Wasim Abbas on 2024-08-23

Reply🗨️Ask a New Question Below❓

If you need your Socapel unit tested or repaired,
give us a call at 1-336-969-0110.
We offer fair estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent Comments


#Socapel by Wasim Abbas on 2024-08-23 07:00
Dear Concern, Please see under below detail then quote rate and also share performa invoice now on first priority.1)SAM-DA-400/480-07N-P4N-E 06 PcsI’m waiting your Quick and positive reply

#Socapel by Bilal on 2021-03-28 10:01
We are facing 2 error in machine very randomly F05F13Can u plz advise us solution fir this error

#Socapel by tariq mehmood on 2021-01-19 11:28
we Face problem in our pam Error code 0B80E010. Please help us in this matter.

#Socapel by abid on 2019-04-21 07:46
i need a SAM-DA-400-50N-P4N-E PLEASE ADVISE IF YOU HAVE AVAILABLE AND WHATS THE PRICE OF THIS.

#Socapel by cesar viglianco on 2016-11-21 17:31
um socapel motorista Olá Eu tenho sam-da-400-07n PRN-em506l conectado a um nuebo motor 0r0d-0029-0 quando desistir de erro resover dá-nos acreditar que nós deve sintonizar o motor com o driver.É possível facilitar o software(ferramentas SAM)

#Socapel by jaswant on 2015-12-16 11:37
dear sir servo drive manual sam-da-400-07 n-p4n- e modal . tests& services ,repairs manual pdf file Please sand my email address. Thanks.

#Socapel by Nisitha on 2015-07-31 06:28
I would be grateful if you could let me know the availability of scapula SAMSAM-DA-400-50N-P4N-E Nisitha Warnakulasuriya

#Socapel by Nisitha on 2015-07-31 06:26
I would be grateful if you could let me know the availability of scapula SAMSAM-DA-400-50N-P4N-E Nisitha Warnakulasuriya

#Socapel by Md.Rashidul Hasan on 2014-02-24 06:36
Dear sir,I would like to inform you that i need socapel-sam smart axis manager SAM-DA-400-50N-P4N-E Drive if this drive is your collection please inform me with price and conditionThank you very much.Md.Rashidul HasanElectrical EngineerZaber & Zubair Fabrics Ltd.mob: 01746399155,01911397522Email: rashidulhm@gmail.com rashidul@znzfab.comWeb: www.nomangroup.comSkype: rashidul

#Socapel by Rashidul Hasan on 2014-02-09 15:19
Dear sir,I would like to inform you that i want to purchase socapel-sam smart axis manager SAM-DA-400-50N-P4N-E 01 pcsIf you have this device pls send your Quotation or offer.Thanks Md.rashidul HasanElectrical EngineerNoman Group of industrieswww.nomangroup.comemail: rashidul@znzfab.com

#Socapel by Rashidul Hasan on 2013-11-30 09:36
Hi Dear,My Machine installed Pam drive but display show ERROR 680F005.plz send error means or send any manual Thank youRashidul HasanElectrical EngineerNoman Group of industries.

#Socapel by amjad on 2012-06-30 11:05
i want a troubleshootin manual of sam drive

#Socapel by mohamed habib on 2012-05-22 08:25
dear sir please send us the availability of inverter power socapel for welding machine for can of tin-plateTHINK YOU BSET REGARD

#Socapel by mustafa colak on 2011-05-13 07:54
socapel-sam smart axis manager SAM-DA-400-50N-P4N-E SAM-DA-400-07N-P4N-ESOCAPEL POWER SUPPLY SAM-PA-400-80-ESOCAPEL-PAM PAM-P1N-H8F-AP-P V10810

#Socapel by Mustafa Çolak on 2010-07-31 11:59
i have a socapel sam-da07 unit to sell

#Socapel by shahzad on 2010-04-29 10:39
sam-da-400-07n-p4n-e-------------------------------------------------------------------------------- Posted by mike on Tuesday, November 11 2008Could I get a list of error codes for this model? I have an error 25 or 52. I also have a pam to plc link lost. all other drives have no error.

#Socapel by Adem Ceyhaner on 2010-03-18 11:10
To Whom that may concern;We have one Socapel PAM Unit which is defecetive and gives error like 0080EE21, 0B80E002 etc.Please let me know that have ever repaired this Unit or not.I am waiting for your helpBEST REGARDSADEM CEYHANERMENDERES TEKSTIL AS / TURKEY

#Socapel by sohail umer on 2010-03-11 12:30
sam and pamp quotation required

#Socapel by Brendan on 2010-01-04 18:04
Hello;We need Socapel SAM and PAM for our machinery as spare parts. If you have or you know the source from where we can get, please let me know at my email addresss; sparesformachines@gmail.com.Would appreciate your prompt response. Thanks.

#Socapel by hussnain on 2009-12-26 07:17
i want to take \"sam drive \" to running condition without connecting pam.please help me Thanks hussnain

#Socapel by JACKELINE on 2009-11-03 16:46
SERVO SOCAPEL AMPLIFIER ST1 /80/310 YNO 9032011677

#Socapel by Leo on 2009-10-06 23:24
With have a problem wiht the sam, tha alar is 2t, corresponding in the manual a problem with the temperature in the motor, but also say wit is posible tha sam is bad. I change the unit and program and continue with the sim error, what is your oppinion, thanks

#Socapel by IMRAN MIAN on 2009-06-16 18:33
Hi Dear, My Machine installed Pam drive but display show ERROR 0B80E002.plz send error means or send any manual best regards,Imran Mian+92 300 2428847

#Socapel by Wilson Gasch Junior on 2009-05-26 14:51
Do you have some representative in Brazil? I have SAM and PAM units in my machine who needs to be repaired.I\'m waiting for your answer,Best regards,Wilson

#Socapel by ALEKSANDER on 2009-05-01 11:08
I have a problem with SAM DA 400-07N-P4N-E on can-bodi line SOUDRONIC.Its alarm 06XXF00E after one hour work.May I resolved this problem ?How much cost this new device?

#Socapel by Addiniamync on 2009-03-23 19:37
I need a driver for my phillips snn6500 wireless netcardor smc2632 wireless net cardI can`t make them run on linpus linux liteplease helpregardsAddiniamync

#Socapel by reza on 2008-12-21 11:25
hican you repair a pam for us.if yes email to me.thanks reza

#Socapel by mike on 2008-11-11 19:20
Could I get a list of error codes for this model? I have an error 25 or 52. I also have a pam to plc link lost. all other drives have no error.

#Socapel by TaceCertieree on 2008-10-31 12:15
Hello, i newbie, anybody can help me?

#Socapel by David Stanton on 2008-08-18 21:45
I have a Socapel 25-310 ac drive that is giving us a #6 fault code on the display and we do not have a listing for that fault.

#Socapel by Ersin Ak on 2008-05-15 12:54
Dear Friendswe need 1 pc. Socapel PAM-P1N-H8F AP-P V10600. If you have one of this Type, please contact us as soon as possible and give your offer.Best RegardsErsin AK

#Socapel by Adem Ceyhaner on 2008-05-02 08:54
Dear Sir ;We have faced with the same problem you mentioned.the first problem is because of the PAM and we could not get rid of the problem.The second problem is because of the Blanket motor you should change the motor beacuse 2b means overcurrent. We have faced with the same problem and solved the problem with changing of the blanket motor.Good luck.

#Socapel by ADEM on 2008-05-02 07:39
We face with the problem that is about communication between PAM and SAM drives. We have S7-300 PLC, 1 PAM and 13 SAM Drives. During running the machine we face a error Head Communication Error(head means SAM drives for this machine) and we observed followwing error on the PAM 0B80E002,0B80E003 or 0B80E01F.We think that this problem is because of the PAM.My question is how can i repair this PAM and Where i buy PAM from.please respond us as soon as possible

#Socapel by Abrar Hussain on 2008-04-04 12:50
The following problem has been displaying quite often on one of our machines for some days. the PAM-controller (PAM-P1N-H8F-AP-P V10800)displays \'0B80E003\' but the SIEMENS S7-315-2DP CPU has no fault. but MACHINE STOP, WHILE ALL THE SAM (SAM-DA-400-07N-P4N-E) ON \" 1\"This is SAM Normal State.what is the cause of this problem and what we can do, before replacing something? Unfortunately, we do not have any software tools for checking the PAM-SAM system, only for the CPU. Also we are facing problem 2b on our SAM unit of main Blanket motor . It happens many times in a week.Please advice.Waiting for your quick reply on e-mail... Sincerely YoursAbrar

#Socapel by Tahir Hussain on 2008-03-20 12:34
Dear,I am looking for following SERVO controllers made by DANAHER MOTION:SAM-DA-400/480-07B-P5N-G (Part # 9032012567)SAM-DA-400/480-14B-P4N-F (Part # 9032010563)Rgds, Tahir Hussain

#Socapel by M.Saleem on 2006-12-11 12:05
The following problem has been occuring quite often on one of our machines for some days. the PAM-controller (PAM-P1N-H8F-AP-P V10810)displays \'0B80E002\' but the SIEMENS S7-315-2DP CPU has no fault. bUT MACHINE STOP, WHILE ALL THE SAM (SAM-DA-400-07N-P4N-E) ON \" 1\" This is SAM Normal State.what is the cause of this problem and what we can do, before replacing something? Unfortunately, we do not have any software tools for checking the PAM-SAM system, only for the CPU. Waiting for your quick reply on e-mail... Sincerely Yours

#Socapel by Andrew on 2006-08-02 12:41
Dear Sir! Sorry for the wrong e-mail address! This one is correct.The following problem has been occuring quite often on one of our machines for some weeks. One Socapel SAM-drive (SAM-DA-400-14N-P1N-D) stops the whole machine and displays \'7\' and \'F\' characters on its 7-segment display. At this time the PAM-controller (PAM-S1N-L4E-AP V10000)displays \'0780F020\' but the SIEMENS S5-115U PLC has no fault. This problem with the SAM can be reset by the PAM or restarting the PLC. According to the PAM-SAM Troubleshooting Guide fault code \'F\' means \'Main CPU fault (fault handler)\'. Which CPU does this refer to, SAM, PAM or PLC? What else can cause this problem and what we can do, before replacing something? Unfortunately, we do not have any software tools for checking the PAM-SAM system, only for the CPU. Waiting for your quick reply on e-mail... Sincerely Yours