I did a loading to PPM1 slot0 and PPM1 in slot1 but the LEDs on PPM1 slot1 are still on.What\'s the problem?I did loading using VT100 terminal.
If you need your Rustronic unit tested or repaired,
give us a call at 1-336-969-0110.
We offer fair estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110
Dear Sirswe are looking for a company which able to change the Rustronic PLC parameters, can you offer us your expert to come to Germany.Best regardsTUBAFrank Krämer
Dear Sir,We are using turbine TB5000 to drive water pump.I want to force the supply valve (SOL-11)and vent valve( SOL-12). But I can not force them by command CHG SOL11,1. When I type this command, the LED on card is on in short time. There is no signal at terminal. What Module must I choose? Why not I_O Module?I also want to control speed by analog input, may I use the PID control?I hope receive your reply soon. Thank you!Best Regards.Do Trong Nghia
We are using turbine TB-5000. Now speed is panel control. I wish control speed by analog input. May I have the program of this method?
Please find below the complete part numbers for the Rustronic vibration modules I required for the Gas Turbine. Module 4509 Part no. : 4509/20 64/07004230/20 950279/1/2 (SR6113/06) (SR6129/06) Module 4502 Part no. : 4502/30 64/07004230/30 950279/1/5 (SR6127/03) (SR6113/23) Module 4504 Part no. : 4504/42 64/07004230/42 950279/1/6 (SR6123/03) Module 4510 Part NO.: 4510/27 64/07004230/27 50279/2/7 (SR6131/02) (SR5946/05) I hope this helps. Please forward me an official quote.Please forward me your e-mail, so I can send you photos of these cards. Kind regards Dilip HutheramE&I Superintendent Newcastle Co-GenerationCell: 083 631 9693Tel: 034 3284488Fax: 034 3284489Email: dilip.hutheram@newcogen.co.za
I have an SCM card PN CT92475A/03 on a rustronic control system that is causing me trouble. The customer has a replacement card with P/N CT92475A/01 and I do not know what the differences are. Can you support?Customer is due to replace this sytem for a woodward micronet in the next four months.Regards.
I have tried to program this pcb for my washing machine, but it keeps coming up with E90 when I turn the machine on, as if it isn\'t programmed. But when I check the program adresses, the data is correct. I have noticed that the software ver. is W2C01551, is there perhaps an other thing that I need to do? other than pressing the two top buttons for saving the data?Best regardsTorben
I did a loading to PPM1 slot0 and PPM1 in slot1 but the LEDs on PPM1 slot1 are still on.What\'s the problem?I did loading using VT100 terminal.
Dear sir with referencve to our organization we have installed Rustronic MKII software RP2 for EGT turbine (European Gas Turbine ) this system generate a message around 4000 for troubleshotting so if i want to know all the message how its create through varuious types of input /output comming from field device from the software ..can u send the document if i give the all details or can u send one person for servicing or checking of all interlock and all those thing so kindly revert back to me on same mailalso send u required all details from our organization mine:- contact details :- hpchavda@rediffmail.com,hpchavda2003@yahoo.comreagrds thanks Hraesh P Chavda Alembic Limited Baroda Gujarat India
Hi Please could you quote me price and delivery on a Rustronic 4509 vibration card.Kind rgeardsSimon Jackson
Bonjour, Monsieur;Afin de me permettre de lire les modules du software, et de bien comprendre le fonctionnement des turbines installées à notre site Sonatrach, j\'ai besoin de m\'envoyer un document qui explique les instructions utilisées dans des modules par exemple ( /*DEF: MODULE:TURBINE_GAS_FUEL; PROT:2; GLOBAL:DISTAG; GLOBAL:DISSTRING; GLOBAL:^LOAD_STRINGS; GLOBAL:^STRINGS_LOADED;*//*DEF: TASK:INI(3); ID:DEFAULT_TSK_ID; PER:1; ACT:MESSLOAD; REQ:^SYMINIT; LET:^NOTANN=1;*//*GOSUB:TSK_STOP; DEACT:MONITOR;/*et merci monsieur;
We have few unit cards CT91002/2 need to repair.Pls estimed cost repair and delivery.Few CT91002 components burnt
Hello! I\'ve got problem with my washing mashine. That\'s alert E90 about 15 seconds after I pushed the start button och nothing else is happend. DATA:Precond elettronica type 451516811Type E.Z Assembly: 132191552Type E.Z Board:124307062SW Ver.:UDA30202T70 WK:52/05 Op:4410
Need Control Logic (Digital and Analog) of Rustronic MKII
Dear Sirwe need a copy of PLC and monitoring program for SGT-100-2s (Typhoon) MK II ; star fuel valve. we will be highly appriciate if you quote us the above software.best regards
#Rustronic by Godfrey Saldanha on 2006-02-20 04:51